Spectrum analysis apparatus

Model: BIX-8802

Modular designed with flexible configuration

Can be used to measure spectrum of light source, solid or liquid material’s transmission spectrum and reflection spectrum

Wavelength can be chosen from 200nm to 1100nm

Customized products is available




Introduction
Specifications
User resources
Order guide

Introduction

BIX-8802 is a spectrum analysis apparatus designed for physics, chemistry, biology, environment labs and scientific research in university and college. It also can be used for industrial spectrum testing. This apparatus can analyze emitting spectrum, transmission spectrum and reflection spectrum. It’s  modular designed with simple structure and flexible configuration.

Emitting Spectrum

The light couples into the spectrometer through the optical fiber directly so that the spectral data of the light source can be obtained.

Applications:

Spectrum of laser

Spectrum of LED

Spectrum of sunlight

Spectrum of other light source


Standard Hg lamp

Order Information

No.

Description

Model#

Qty.

Notes

1

FiberSpectrometerWavelength 200nm-1100nmOptical resolution 0.1nm-1nm

BIM-60/BIM-66 series

1

Determined by the wavelength and resolution

2

Quartz Optical, L1.5m, Φ600μm

BIM-6102

1

-

Liquid samples transmission spectrum

Using the spectrometer to measure the tungsten as reference spectrum, it can measure the sample’s transmission spectrum. Then you can get the transmissivity curve and absorptivity curve by the software.

Applications

The component analysis and concentration measurement of chemicals, food or water


Reference spectrum                                       Transmission spectrum of CuSO4 solution

Order Information

No.

Description

Model#

Qty.

Notes

1

Fiber Spectrometer, Wavelength 200nm-1100nm, Optical resolution 0.1nm-1nm

BIM-60/BIM-66 series

1

Determined by the wavelength and resolution

2

Quartz Optical, L1.5m, Φ600μm

BIM-6102

2

-

3

Tungsten Light Source, with the focusing lens, 400nm-2000nm, 10W

BIM-6202

1

-

4

10dB Attenuator

BIM-7921

1

-

5

Cuvette mount

BIM-6305

1

-

6

Plastic Cuvette, 12.5 mm×12.5 mm×45 mm, (6EA)

BIM-6301

1

-

7

Samples

-

-

User-supplied

Solid samples transmission analysis


Using the spectrometer to measure the tungsten as reference spectrum, it can measure the sample’s transmission spectrum. Then you can get the transmissivity curve by the software.



Reference spectrum Transmission spectrum of filter

Applications

The transmissivity, central wavelength and bandwidth of optical filter, sunglasses or car window films

Component analysis of solid samples

Order Information

No.

Description

Model#

Qty.

Notes

1

FiberSpectrometer,Wavelength200nm1100nm,Optical resolution 0.1nm-1nm

BIM-60/BIM-66 series

1

Determined by the wavelength and resolution

2

Quartz Optical, L1.5m, Φ600μm

BIM-6102

2

-

3

Tungsten Light Source, with the focusing lens, 400nm-2000nm, 10W

BIM-6202

1

-

4

10dB Attenuator

BIM-7921

1

-

5

Solid Sample Transmission Mount, L300mm

BIM-6302

1

-

6

Samples

-

-

User-supplied

Solid samples reflection analysis

Using the spectrometer to measure the tungsten as reference spectrum, and then measure the sample’s reflection spectrum. The reflectance curve will be got by software.


Reference spectrum Reflection spectrum of red paper

Applications

Component analysis of solid samples

Color measurement of paper, textile or oil paint (Developing)

Order Information

No.

Description

Model#

Qty.

Notes

1

Fiber Spectrometer,Wavelength 200nm-1100nm,Optical resolution 0.1nm-1nm

BIM-60/BIM-66 series

1

Determined by the wavelength and resolution

2

Reflection Quartz Fiber (Single Core), L 1.5m, Φ600μm

BIM-6103

2

-

3

Tungsten Light Source, with the focusing lens, 400nm-2000nm, 10W

BIM-6202

1

-

4

Double Channels Reflection Mount Φ150mm×13mm

BIM-6303

1

-

5

Diffuse Reflectance Standard,Φ40mm, R97% (350nm-2000nm)

BIM-6304

1

-

6

Samples

-

-

User-supplied

Specification

Description

Model#

Parameters

Fiber Spectrometer

BIM-60/BIM-66 series

Please see Fiber Spectrometer's introduce

Quartz Optical

BIM-6102

L1.5m, Φ600μm

Tungsten Light Source

BIM-6202

With the focusing lens, 400nm-2000nm, 10W; Maximum voltage: 12V DC; 2000 hours; SMA905 connector; Dimension: 100mm × 60mm × 34.5mm; 0.2Kg

Cuvette mount

BIM-6305

140mm*140mm*40mm

Plastic Cuvette

BIM-6301

6EA, 12.5 mm×12.5 mm×45 mm

SolidSample Transmission Mount

BIM-6302

200mm*78mm

Double Channels Reflection Mount

BIM-6303

Φ150mm×13mm

Diffuse Reflectance Standard

BIM-6304

Φ40mm, R97% (350nm-2000nm)

Reflection Quartz Fiber

BIM-6103

Single Core, L 1.5m, Φ600μm


Parts List

No.

Description

Moel#

Qty.

1

Fiber Spectrometer,Wavelength 200nm-1100nm,Optical resolution 0.1nm-1nm

BIM-60/BIM-66 series

1

2

Quartz Optical, L1.5m, Φ600μm

BIM-6102

1

3

Reflection Quartz Fiber (Single Core), L 1.5m, Φ600μm

BIM-6103

2

4

Tungsten Light Source, with the focusing lens400nm-2000nm, 10W

BIM-6202

1

5

10dB Attenuator

BIM-7921

1

6

Plastic Cuvette, 12.5 mm×12.5 mm×45 mm,(6EA)

BIM-6301

1

7

Solid Sample Transmission Mount, L200mm

BIM-6302

1

8

Double Channels Reflection Mount Φ150mm×13mm

BIM-6303

1

9

Diffuse Reflectance Standard,Φ40mm, R97% (350nm-2000nm)

BIM-6304

1

10

Cuvette mount

BIM-6305

1



User's Manual Download



Spectrum analysis apparatus  (BIX-8802) Manual

Zip.MB



Order Information

Description

Model#

Qty.

spectrum analysis apparatus300-800nmresolution1nm

BIX-8802-11

1

spectrum analysis apparatus400-1100nmresolution1nm

BIX-8802-12

1

spectrum analysis apparatus200-900nmresolution1nm

BIX-8802-21

1

In addition to the above order number, the other specifications of spectrometer can also be chosen. Please refer to the products introduction.